Heltec Lithium Battery Capacity Tester 5V 50A Battery Load Bank Charge/Discharge Unit
- Estimated Delivery : Up to 4 business days
HT-BCT50A 5VHeltec Lithium Battery Capacity Tester 5V 50A Battery Load Bank Charge/Discharge Unit
Product Information:
📌 Product Highlights
✅ All-in-One Multi-Mode:Charge + Discharge + Cycle + Balancing, 4 modes in 1 device, meet all testing needs!
✅ Ultra-Wide Compatibility:0.3-5V & 1-2000Ah range, support ALL mainstream lithium batteries!
✅ Professional High Precision:0.1% voltage accuracy, ±1.5% capacity error, meet industry testing standards!
✅ Comprehensive Safety Protection:5-layer protection, avoid all misuse risks, safe for long-time use!
✅ Intelligent Visual Design:Clear real-time display, easy parameter adjustment, beginners can get started quickly!
✨ 4 Core Advantages You Can’t Miss
1. All-in-One Working Modes, Meet All Your Needs
- CC-CV Charging Mode: Customize voltage & current to fit ANY battery’s charging rules perfectly!
- MOS Tube Discharge Mode: Stable 0.5-50A output to test REAL battery capacity, no fake data!
- Cycle Mode: Simulate real use for multiple charge-discharge cycles, evaluate battery life accurately!
- Balancing Mode: Improve battery pack consistency, extend its service life greatly!
2. Wide Compatibility, Cover All Scenarios
- Supports NCM, LFP, LTO & ALL mainstream lithium batteries—from small digital cells to large energy storage cells, from power cells to DIY battery packs!
- 0.3-5V wide voltage & 1-2000Ah large capacity range—meet ALL your testing needs, no need for multiple devices!
3. 5-Layer Safety Protection, 100% Safe Use
- Reverse Polarity Protection: No damage even if connected reversely! Built-in circuit protects both device and battery!
- Overvoltage & Overcurrent Protection: Automatically shut down when exceeding limits, avoid overcharge/overcurrent damage!
- Battery Disconnection Protection: Stop testing immediately if battery disconnects, avoid no-load risk!
- High Temperature Protection: Intelligent fan & temperature control, stable operation for long-time use!
4. High-Precision & Visual Display, Professional Results at a Glance
- Industry-leading accuracy: 0.1% voltage, 0.2% current, ±1.5% capacity error—meet professional testing standards!
- Real-time visual display: Show running time, temperature, voltage, current, capacity and charge-discharge curve clearly—no professional background needed to read data!
- Calibratable design: Long-term accuracy guarantee, maintain professional testing performance for years!
Product Introduction:
The battery charge and discharge capacity tester’s appearance introduction:
1. Power switch: If the power is suddenly cut off during the test, the test data will not be saved.
2. Display screens: Display charging and discharging parameters and discharge curve.
3. Coding switches: Rotate to adjust working mode, press to set parameters.
4. Start/Stop button: Any operation in running state must be paused first.
5. Battery positive input: 1-2-3 pin through current, 4 pin voltage detection.
Use method:
The battery charge and discharge capacity tester using method:
1. Start up first, and then clip the battery. Press the setting knob to enter the setting page, rotate left and right to adjust the parameters, press to determine, Set the parameters correctly and save the exit.
The battery charge and discharge capacity tester’s parameters that need to be set in various modes
Parameters to be set in Charging mode:
Charging End voltage: lithium titan ate 2.7-2.8V, 18650/ternary/polymer 4.1-4.2V, lithium iron phosphate 3.6-3.65V (You must set this parameter correctly and reasonably).
Charging current: set to 10-20% of the cell capacity (Please set it correctly and reasonably) It is recommended to set a current that makes the cell heat less as much as possible.
Judging full current: that is when the charging current is less than this value, it is judged to be fully charged. It is recommended that the battery cell below 5Ah be set to 0.2A, the battery cell of 5-50Ah should be set to 0.5A, and the battery cell above 50Ah should be set to 0.8A.
Parameters to be set in Discharge mode:
Discharge End voltage: lithium titan ate 1.6-1.7V, 18650/ternary/polymer 2.75-2.8V, lithium iron phosphate 2.4-2.5V (You must set this parameter correctly and reasonably).
Discharge current: set to 10-50% of the cell capacity (Please set it correctly and reasonably)
It is recommended to set a current that makes the cell heat less as much as possible.
Parameters to be set in Cycle mode:
Charge and discharge mode parameters need to be set simultaneously
Keep voltage: The cut-off voltage of the last charge in cyclic mode ,can be the same as the cut-off voltage of the charge or discharge.
Resting time: In cycle mode, after the battery is fully filled or discharged (let the battery cool down for a period of time), usually set for 5 minutes.
The battery charge and discharge capacity tester’s cycle: Max 5 times,
1 time (charge-discharge-charge),
2 times (charge-discharge-charge-discharge-charge),
3 times (charge-discharge-charge-discharge-charge-discharge-charge).
Parameters to be set in Voltage balancing mode:
Discharge End voltage: How many volts do you plan to balance the cell voltage to?
This value must be higher than 10mv than the battery voltage.
Discharge current setting reference: Less than 10% of the cell capacity is recommended.
End current: It is recommended to set it to 0.01A.
2.Return to the home page, rotate the setting button to the left or right to the working state, and press again to pause.
3.After waiting for the test to end, the result page will automatically pop up (press any button to stop the alarm sound) and record it manually. Test the results, and then test the next battery.
The battery charge and discharge capacity tester’s test results: 1 indicates the first cycle, the AH/WH/min of charge and discharge respectively. Press the start / stop button further to show the results and curve of each step in turn.
The yellow numbers represent the voltage axis, and the yellow curve represents the voltage curve.
Green numbers represent the current axis, green numbers represent the current curve.
When the battery performance is good, the voltage and current should be a relatively smooth curve. When the voltage and current curve rises and falls sharply, it may be that there is a pause during the test or the charging and discharging current is too large. Or the internal resistance of the battery is too large and it is close to being scrapped。
If the test result is empty, the working step is less than 2 minutes, so the data will not be recorded.
Accessories:
This fixture in the second picture needs to be bought separaly.
Precautions:
Heltec HT-ABT50A battery charge and discharge capacity tester’s clamp using methods
1. Both the large and small crocodile clamps must be clamped on the battery pole lugs!
2. The contact area between the large crocodile clip and the pole ear should be large enough, and it is prohibited to clip it onto screws/nickel plates/wires, otherwise it will cause abnormal interruption of the testing process!
3. The small crocodile clip must be clamped at the bottom of the battery ear, otherwise it may cause inaccurate capacity testing!
Jacqueline: jacqueline@heltec-bms.com / +86 185 8375 6538
Vivian: sales7@heltec-bms.com / +86 135 5108 9621
Nancy: nancy@heltec-bms.com / +86 184 8223 7713
| Weight | N/A |
|---|---|
| plug | 220V (European Standards plug), 110V (US plug), Fixture |
| ship from | CN, PL(Europe Only, UK excluded), US(US Only), AU(Australia Only), RU(Russian Only) |
Be the first to review “Heltec Lithium Battery Capacity Tester 5V 50A Battery Load Bank Charge/Discharge Unit”
You must be logged in to post a review.



































Reviews
There are no reviews yet.